909722.fm

M. K. JUCHHEIM GmbH & Co
JUMO Instrument Co. Ltd.
JUMO PROCESS CONTROL INC.
Data Sheet 90.9722
Terminal heads and blocks
for thermocouples and resistance thermometers
terminal heads in different materials
Protection IP65 max.
versions for lead sealing
Terminal heads (pages 1 to 4)
DIN 43 729 specifies the terminal head forms A and B, which differ in size and also slightly
in shape. The nominal diameter of the bore to take the protection tube is 22 or 32mm for
Form A, and 15mm or thread M 24x1.5 for Form B.
Either aluminium or plastic is used according to the application. Terminal head form B as
per DIN is more widely used. The additional forms J, JK, BBK and BUZ are derived from
the DIN form to meet particular requirements. These forms (except JK) are suitable for in-
stalling a 2-wire transmitter. Form JK already incorporates terminals.
Terminal blocks (pages 5 and 6)
Suitable terminal blocks with two, four or six connections are available for the different ter-
minal heads.
Note: please state sales no. as per price sheet 90.9722 when ordering!
Terminal heads to DIN 43 729, Form A
IP54 protection

Diameter
Temperature
Terminal head Form A 22
aluminium die-casting

Terminal head Form A 32

Note: versions up to 200°C on request
M. K. JUCHHEIM GmbH & Co
JUMO Instrument Co. Ltd.
JUMO PROCESS CONTROL INC.
Data Sheet 90.9722
Terminal heads to DIN 43 729, Form B
IP54 protection

Diameter
Temperature
Terminal head Form B 15
aluminium die-casting

Terminal head Form B M 24x1.5

Note: versions up to 200°C on request.
Terminal head similar to DIN 43 729, Form B
IP65 protection

Diameter
Temperature
Terminal head Form BUZ M 24x1.5
aluminium die-casting

M. K. JUCHHEIM GmbH & Co
JUMO Instrument Co. Ltd.
JUMO PROCESS CONTROL INC.
Data Sheet 90.9722
Terminal heads suitable for lead sealing, JUMO version, Form J
IP54 protection

Diameter
Temperature
Terminal head Form J
aluminium die-casting


Note: versions up to 200°C on request
Terminal head similar to DIN 43 729, Form B
IP54 protection

Diameter
Temperature
Terminal head Form BBK M 24x1.5
PPO plastic

M. K. JUCHHEIM GmbH & Co
JUMO Instrument Co. Ltd.
JUMO PROCESS CONTROL INC.
Data Sheet 90.9722
Terminal heads suitable for lead sealing, JUMO version, Form JK
IP53 protection

Diameter
Number of
Temperature
connections
Terminal head Form JK M 24x1.5 PTMT plastic
for thermocouples with screw terminals

Terminal head Form JK M 24x1.5 PTMT plastic
for resistance thermometere with solder terminals
M 24x1.5
Terminal head, Form BUZH
IP65 protection

Diameter
Temperature
Terminal head Form BUZH
aluminium die-casting with screw cover

M. K. JUCHHEIM GmbH & Co
JUMO Instrument Co. Ltd.
JUMO PROCESS CONTROL INC.
Data Sheet 90.9722
Terminal blocks with screws and seal
for terminal heads Form A

Number of
Thermocouple
terminals
Terminal blocks for thermocouples
Terminal blocks
for terminal heads Form B, BBK, BUZ and BUZH

Number of
terminals
Terminal block for thermocouples
Terminal block for resistance thermometers

Note: screws and seals on request
M. K. JUCHHEIM GmbH & Co
JUMO Instrument Co. Ltd.
JUMO PROCESS CONTROL INC.
Data Sheet 90.9722
Terminal blocks
for terminal heads Form J

Number of
terminals
Terminal blocks for thermocouples and resistance thermometers

Note: screws amd seals on request

Source: http://www.interconex.ro/fckfiles/file/senzori-de-temperatura/accesorii/2-capete-si-blocuri-terminale.pdf

Produits ménager mars 2014x

LDS SERVICES- Rue des Etangs - BP21 - 76340 - Blangy-sur-Bresle Tel:(0)9 64 22 05 39/ Fax:(0)2 35 94 64 55/ Mob:(0)6 07 46 80 12/ ldsservices@orange.fr Bon de Commande Mars 2014 livraisons a partir de début Avril FOURNITURES HYGIENE & ENTRETIEN 1 24(8 x 3) Rouleaux essuie tout double feuille bonne qualité 122 24(2x12) Rouleaux papier toilette bonne qualité blanc dou

Microsoft word - non-surgical.docx

Non-Surgical/Medical Abortions: Ru-486/Mifeprex Abortion Pill, Methotrexate Injection Non-surgical / medical abortion or abortion by pill is a relatively new method of termination of pregnancy for early pregnancies (below 7-9 weeks of pregnancy from the first day of the last menstrual period, confirmed by ultrasound dating). Even prior to RU-486 or Mifeprex , our very experienced, New

Copyright 2014 Pdf Medic Finder