Microsoft word - man0369-05.doc

MAN0369-05
10 NOV 2006
DIM310/410
12 / 24VDC Input Module
HE800DIM310 / HE800DIM410
HE-DIM310* / HE-DIM410*
16 / 32 Channels
Positive or Negative Logic
* HE- denotes plastic case.
This datasheet also covers products starting with IC300. 1 SPECIFICATIONS
See Compliance Table at http://www.heapg.com/Support/compliance.htm Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. 10 NOV 2006
MAN0369-05
DIM310/410
DIM310 / DIM410 Wiring
OCS Bottom View – Shows
Corresponding I/O Pin
DIM310/410 INPUT
Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. MAN0369-05
10 NOV 2006
DIM310/410
2.2 DIM410
OCS Top View – Shows
Corresponding I/O pin
DIM410 INPUT
Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. 10 NOV 2006
MAN0369-05
DIM310/410
3 INTERNAL
4 CONFIGURATION
Preliminary configuration procedures that apply to SmartStack™ Modules are contained in the hardware manual of the controller you are using. Refer to the Additional References section in this data sheet for a listing of hardware manuals. Although the module has no user defined parameters, the I/O Map describes which I/O registers are assigned to a specific SmartStack™ Module and where the module is located in the point map. The I/O Map is determined by the model number and location within the SmartStack™. The I/O Map is not edited by the user. CHARACTERISTICS
Digital Input Chart
0 .125(±15%) V-A
Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. MAN0369-05
10 NOV 2006
DIM310/410
INSTALLATION / SAFETY
Warning: Remove power from the OCS controller, CAN port, and any peripheral equipment
connected to this local system before adding or replacing this or any module.
Use the following wire type or equivalent: For detailed installation and a handy checklist that covers panel box layout requirements and minimum clearances, refer to the hardware manual of the controller you are using. (See the Additional References section in this document.). When found on the product, the following symbols specify: Warning: Consult user documentation.
Warning: Electrical Shock Hazard.
WARNING: To avoid the risk of electric shock or burns, always connect the safety (or earth)
ground before making any other connections.
WARNING: To reduce the risk of fire, electrical shock, or physical injury it is strongly
recommended to fuse the voltage measurement inputs. Be sure to locate fuses as close to the
source as possible.
WARNING: Replace fuse with the same type and rating to provide protection against risk of fire
and shock hazards.
WARNING: In the event of repeated failure, do not replace the fuse again as a repeated failure
indicates a defective condition that will not clear by replacing the fuse.
WARNING: Only qualified electrical personnel familiar with the construction and operation of
this equipment and the hazards involved should install, adjust, operate, or service this
equipment. Read and understand this manual and other applicable manuals in their entirety
before proceeding. Failure to observe this precaution could result in severe bodily injury or loss
of life.
Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. 10 NOV 2006
MAN0369-05
DIM310/410
For detailed installation and a handy checklist that covers panel box layout requirements and minimum clearances, refer to the hardware manual of the controller you are using. (See the Additional References section in this document.): • All applicable codes and standards need to be followed in the installation of this product. • For I/O wiring (discrete), use the following wire type or equivalent: Belden 9918, 18 AWG or Adhere to the following safety precautions whenever any type of connection is made to the module. • Connect the green safety (earth) ground first before making any other connections. • When connecting to electric circuits or pulse-initiating equipment, open their related breakers. Do not make connections to live power lines. • Make connections to the module first; then connect to the circuit to be monitored. • Route power wires in a safe manner in accordance with good practice and local codes. • Wear proper personal protective equipment including safety glasses and insulated gloves when making connections to power circuits. • Ensure hands, shoes, and floor are dry before making any connection to a power line. • Make sure the unit is turned OFF before making connection to terminals. Make sure all circuits are de-energized before making connections. • Before each use, inspect all cables for breaks or cracks in the insulation. Replace Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. MAN0369-05
10 NOV 2006
DIM310/410
7 ADDITIONAL
REFERENCES
The following information serves as a general listing of Horner controller products and other references of interest and their corresponding manual numbers. Visit our website listed in the Technical Support section to obtain user documentation and updates. Note: This list is not intended for users to determine which products are appropriate for their
application; controller products differ in the features that they support. If assistance is required,
see the Technical Support section in this document.
Controller Manual
LX Series (e.g., LX-xxx; also covers RCS116) OCS (Operator Control Station) (e.g., OCS1xx / 2xx; Graphic OCS250) Remote Control Station (e.g., RCS2x0) MiniOCS (e.g., HE500OCSxxx, HE500RCSxxx) Other Useful References
Wiring Accessories and Spare Parts Manual Wiring Accessories and Spare Parts Manual Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. 10 NOV 2006
MAN0369-05
DIM310/410
8 TECHNICAL
For assistance and manual up-dates, contact Technical Support at the following locations: North America:+
Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC.

Source: http://actionarielectrice.ro/web_continut/fisiere/Xle/MAN0369-05.pdf

Metadoze v pi

Only for the use of a Registered Medical Practitioner or a Hospital or a Laboratory. Metformin Hydrochloride and Voglibose Tablets METADOZE V- 0.2/0.3 METADOZE V - 0.2 Distribution: COMPOSITION After ingestion of voglibose (and other glucosidase inhibitors), the majority of active Each uncoated bi-layered tablet contains unchanged drug remains in the lumen of the gastrointestinal t

Microsoft word - 1 - ocon1372titlepi.doc

CHAPTER 6 CIVIL RIGHTS Narrative Lecture Outline The term "civil rights" refers to the positive acts governments take to protect individuals against arbitrary or discriminatory treatment by government or individuals. Since the Constitution was written, the conception of civil rights has changed dramatically. The addition of the Fourteenth Amendment after the Civil War made equ

Copyright 2014 Pdf Medic Finder